Add to Cart
The CM/CY series charge controllers is the highlight in the range.
Use of the latest charging technologies combined with state of charge determination enable optimal battery maintenance and module power monitoring for up to 2880 Wp of connected power. A large display informs the user about all operating modes with the aid of symbols. The state of charge is represented visually in the form of a tank display. Data such as voltage, current and state of charge can also be displayed digitally as figures on the display.
4Integrated data logger energy meter 4Automatic detection of voltage 4PWM control 4Multistage charging technology 4Automatic load reconnection 4Temperature compensation | 4Overcharge protection 4Deep discharge protection 4Reverse polarity protection
|
echnical datasheet
Model | CM3024 CY30A-24 | CM5024 CY50A-24 | CM3048 CY30A-48 | CM5048 CY50A-48 | CM6024 CY60A-24 | CM6048 CY60A-48 | ||
Rated current | 30A | 50A | 30A | 50A | 60A | 60A | ||
Rated voltage | 12/24V | 12/24V | 48V | 48V | 12/24V | 48V | ||
Max solar voltage | <50V | <50V | <100V | <100V | <50V | <100V | ||
Low voltage disconnect | 10.7/21.4V | 42.8V | 10.7/21.4V | 42.8V | ||||
Low voltage reconnect | 12.6/25.2V | 50.4V | 12.6/25.2V | 50.4V | ||||
Float charge | 13.7/27.4V | 54.8V | 13.7/27.4V | 54.8V | ||||
Standby loss | <30mA | |||||||
Charging mode | PWM | |||||||
Temp compensation | -4mV/Cell/℃ | |||||||
Opearating condition | -20℃~+60℃ | |||||||
Size/Weight | CM3024 CM3048 | 90x188x48 360g | CY30A-24 CY30A-48 | 110*170*55 300g | ||||
CM5024 CM6024 CM5048 CM6048 | 130x188x62 590g | CY50A-24 CY50A-48 CY60A-24 CY60A-48 | 130x188x62 570g |